HMS - Anybus MBTCP slave to CC-Link IE Field - AB7958

KopiërenKopiëren
HMS - Anybus MBTCP slave to CC-Link IE Field
€ 829,00

door St.

€ 829,00

1

Levering

Aantal beschikbare items voor levering:0

Verpakking

  • 1 St.

EAN

Ref Routeco

AB7958

Ref leverancier

AB7958

Ref commercieel

AB7958

Anybus X-gateway – CC-Link IE Field Slave - Modbus TCP Server


  • Features and benefits
  • Fast copying of cyclic I/O data between the two networks (10-15 ms)
  • Proven and tested with all PLC manufacturers
  • Supports up to a maximum of 512 bytes of Input and Output data in each direction
  • Possibility to build web pages displaying and controlling a factory floor process with data from the other connected network
  • Fast, dynamic transfer of fieldbus data to e.g. SCADA/HMI/Enterprise level systems based on Microsoft Windows, via the included Anybus OPC server
  • Optional control status information added to I/O data for diagnostic purposes
  • Robust stand-alone housing for use in harsh industrial environments
  • Global free technical support and consultancy
  • CC-Link IE Field interface
  • CC-Link IE Field Slave settings can be made either via on-board switches, or by importing the provided .CSP file into engineering tool of the controlling PLC.
  • CC-Link IE Field interface of the X-gateway is conformance tested and approved by CLPA
  • CC-Link Specification (Profile), publication BTP-05028-B
  • Acts as a CC-Link IE Field Network Intelligent Device Station
  • Max 512 bytes Input and 512 bytes I/O data
  • On CC-Link IE Field: Max of 832 I/O points and 204 words Input and 832 I/O points and 204 words Output
  • Baudrate 1 Gbit/s fixed operation
  • TCP/IP settings configurable with web-page, Configuration Tool, DHCP or ARP
  • CC-Link IE Field station setting via on-board switches
  • 2x RJ-45 ports available simultaneously
  • Modbus TCP Slave interface
  • Modbus TCP Slave settings can be made either via the built-in web interface, or by importing the provided .EDS file into engineering tool of the controlling PLC.
  • Conforms to Modbus TCP v1.0
  • Modbus TCP class 0, class 1 and partially class 2 slave functionality
  • 10/100Mbit operation in full or half-duplex
  • Integrated FTP server provides easy file management using standard FTP clients
  • Web server with dynamic data capability and Server Side Include (SSI) capability
  • Email client with dynamic data capability and Event-triggered email handling
  • Per-user security framework
  • Quality of Service (QoS) available
  • DNS Capability
  • TCP/IP settings via DHCP/ARP/Anybus IPconfig (HICP)
  • Integrated switch allowing for a daisy-chain topology
  • 2x RJ-45 ports available simultaneously.